Product description
Model IV2-G500MA
Type Standard model
Reference distance 20 to 500 mm 0.79″ to 19.69″
Field of view
Installation distance of 20 mm 0.79″:
10 (H) × 7.5 (V) mm 0.39″ (H) × 0.30″ (V) to
Installation distance of 500 mm 19.69″:
200 (H) × 150 (V) mm 7.87″ (H) × 5.91″ (V)
Indicators 2 (the same display details for both indicators)
Image receiving element
Type 1/3 inch monochrome CMOS
Number of pixels 752 (H) × 480 (V)
Focus adjustment Automatic
Exposure time 1/10 to 1/50000
Lights
Illumination White LED
Lighting method Switchable between pulse lighting and DC lighting
Environmental resistance
Enclosure rating IP67
Ambient temperature 0 to +50°C 32 to 122°F (No freezing)
Relative humidity 35 to 85% RH (No condensation)
Vibration resistance 10 to 55 Hz; double amplitude 1.5 mm 0.06″; 2 hours in each of the X, Y, and Z directions
Shock resistance 500 m/s2 1640.4’/s2, 6 times in each of the 3 directions
Material Main Unit, case: Zinc die-casting, Front cover: Acrylic (hard coat), Operation indicator cover: TPU
Weight Approx. 75 g